In combination with the LED-Panel, the iQ-AF Box is used for low light / bright light shutter delay measurements of digital cameras. By using the two rotary control units, it is possible to switch from one light level to the other immediately. Essentially, two different light levels can be preset by just using a switch without remeasuring the illumination level again.
Timing Measurement according to ISO 15781
Combine the LED-Panel, iQ-Trigger and the iQ-AF Box, and you get an even more powerful set of tools to measure shutter-lag and shooting-lag. It can be arranged in a way, that it meets the requirements of the new ISO standard 15781.
Illumination level | 20 - 3200 Lux |
Size of used test chart | A1066 (124.5 x 83.5 cm) |
Provided test charts | TE261 or other |
Lamps | 4 pcs. 18 W and 4 pcs. 36 W D50 (can be switched on/off separately) |
Setting of light level | two rotary control units |
Weight | approx 30 kg |
Outer dimensions w / h / d | 128 x 86.5 x 87 cm |