  1. Image Quality News - June 2022

    benefits all camera testing, including tests with very short exposure times, e.g., automotive-grade cameras. High dynamic range testing Very short exposure time testing Extremely stable Various flicker modes This device is perfect for those looking for...

  2. Image Quality News - August 2022

    for HDR testing The LG3 can illuminate a high contrast test target with over 150,000 lx making measurements of a high dynamic range possible with short, practical exposure times. Normal mode: 0-100% 32 kHz / 100 to 65,000 lx Low mode: 0-100% 32 kHz / 10...

  3. The three traits that guide our test lab

    For over 20 years, our test lab has been testing and analyzing the image quality of digital cameras. Since the beginning, we have always used three characteristics to guide our camera assessments. “It is exciting to work in the test laboratory at Image...

  4. TE294

    A unique test chart designed for the Vega illumination device TE294 is a unique grayscale test chart for high precision measurements such as those used to evaluate the performance of automotive camera systems. This chart has been developed to be used...

  5. TEXX

    Can’t find the correct chart for your testing requirements? Create a custom test chart. Looking for a custom test chart? We currently produce 250+ test charts that cover the full spectrum of image quality testing. These charts cover everything from a...

  6. Weather control and image quality testing

    chart. This chart allows us to test numerous image quality factors such as resolution, texture loss, color accuracy, dynamic range, noise, and distortion in one test image. We recommend illuminating the test chart using the iQ-Flatlights, powered by...

  7. About Image Engineering

    to a new business location in Kerpen, Germany. 2014 Introduction of the modular lightSTUDIO with moving parts and high dynamic range capabilities. Introduction of the iQ-Analyzer version 6. 2013 Introduction of iQ-LED technology, a spectrally tunable...

  8. iQ lab

    measure and provide it Whatever information you need about an imaging system - whether resolution, spectral sensitivity, dynamic range, color reproduction, image stabilization, noise or timing – the iQ lab can measure it. Latest available international...

  9. camSPECS

    filters. The light source is designed to ensure equal power output for the interference filters and to not exceed the dynamic range of the camera. Neutral density filters in the front plate are used to compensate for possible non-uniformities of...

  10. CAL4

    for measuring endoscopic light sources in the medical area. The CAL4 is designed for measuring resolution, color, OECF, dynamic range and noise when using an endoscopic light source. The 0,3m integrating sphere provides a uniform illumination over the...

  11. Image Quality News - November 2022

    benefits all camera testing, including tests with very short exposure times, e.g., automotive-grade cameras. High dynamic range testing Very short exposure time testing Extremely stable Various flicker modes This device is perfect for those looking for...

  12. Time-of-Flight Calibration - Technology

    Time-of-Flight Characterization Technology Introduction Time-of-flight (ToF) camera technology refers to the ability of the camera and sensor system to accurately determine object distances in the field-of-view (FoV) and 3D map the scene. This...

  13. Camera Timing Mesurements

    quality test. With this chart, you can measure image quality factors such as resolution, texture loss, color accuracy, dynamic range, and the critical timing parameters in one test image. This chart is also designed to be used in low-light test...

  14. Image Quality News - September 2023

    to challenge sensors with very high sensitivity. This development is essential for today's image sensors and high dynamic range configurations that make testing at or close to sensor saturation difficult. We will release more information on Arcturus in...

  15. TE259

    OECF/Noise Chart with 20 gray patches contrast 10000:1 The TE259 is designed to check the dynamic range of broadcast cameras on a waveform monitor. It contains a gray step wedge with 20 patches and a contrast range of 10,000:1. The TE259 is supported...

  16. TE42

    camera testing The TE42 V2 is a multipurpose test chart for the analysis of resolution, texture reproduction, acutance, dynamic range, noise, color reproduction, distortion, shading, chromatic aberration, and a visual analysis. Over the years, it has...

  17. Noise: SNR vs. visual noise

    solution. For each patch, you get a VN value. TE264, the ISO standard chart to measure OECF, SNR, Visual Noise and dynamic range. The iQ-Analyzer with Visual Noise result Different colors reflect the Visual Noise for different viewing conditions. Cyan...

  18. Chart sizes & standards

    still-picture imaging - Noise measurements ISO 21550 Electronic scanners for photographic images - Dynamic range measurements DIN 19045-1 Projektion von Steh- und Laufbild - Projektions- und Betrachtungsbedingungen DIN 19051-2 Testvorlagen für die...

  19. Signal to noise in linear and non-linear systems

    Often times the dynamic range that gets reported by imaging sensor manufacturers is based on the max output signal divided by the noise in the dark areas also called the noise equivalent power. The noise equivalent power describes the signal level...

  20. EMVA 1288

    methods, a test according to the standard gives these numbers: RESPONSE • Quantum efficiency • Non-Linearity-Error • Dynamic Range • Saturation capacity NOISE AND NON-UNIFORMITY • Dark Signal NonUniformity (DSNU) • Signal to Noise ratio (SNR) • Pixel...