Key Benefits
Product Variants
We offer many different variants of the lightSTUDIO with assorted features and lighting options.
Use Case
Product Video
Technical Specifications
| lightSTUDIO-L | lightSTUDIO-L IR | lightSTUDIO-L 850/940 nm | lightSTUDIO-AW | |
|---|---|---|---|---|
| Light sources | 10 x iQ-LED V2 | 41 SMD high-power LEDs | 5 x iQ-LED V2 | 41 SMD high-power LEDs | 10x iQ-LED-IR | 11 additional IR LED channels | 10 x iQ-LED V2 | 41 SMD high-power LEDs | 5 x iQ-LED 850 and 5 x iQ-LED 940 | 4 SMD high-power LEDs | Image Engineering AW Light Source Technology (AW for Adaptive White) |
| Intensity | Intensity adjustable in 4000 steps per channel with 32 kHz PWM (switchable to 1000 steps with 128 kHz) | Controlled via 4000 steps per channel and 32 kHz PWM (switchable to 1000 steps with 128 kHz) | Intensity adjustable in 4000 steps per channel with 32 kHz PWM (switchable to 1000 steps with 128 kHz) | 2 lx – 1800 lx (1AW90 Head) 4 lx – 3600 lx (2AW90 Head) 1.5 lx – 1700 lx (1AW95) 3 lx – 3400 lx (2AW95) |
| Spectral Range | 380-820 nm | 380-1050 nm | 380-820 nm | - |
| Predefined standard illuminants | D50, D55, D65, D75, A, B, C, E - Create a Planckian spectral curve utilizing a selected temperature (1900 - 18,000 K) | D50, D55, D65, D75, A, B, C, E - Planckian spectral curve by selected temperature (1900 – 18,000 K) | D50, D55, D65, D75, A, B, C, E - Planckian spectral curve by selected temperature (1900 – 18,000 K) | 2700-6500 K (depending on variant) |
| Illumination stability | +/-1% when stabilized (2% after switching D illuminants in the first 5 seconds) | iQ-LED V2: +/- 1% when stabilized (2% after switching D illuminants in the first 5 seconds) iQ-LED IR: +/- 2% when stabilized | +/- 1% when stabilized (2% after switching D illuminants in the first 5 seconds) | Stabilization time of <1.8 seconds per 1% intensity change Stabilization time is 0 seconds for a change in color temperature |
| Response time (switch illuminant) | < 50 ms | < 50 ms | < 50 ms | Manual control via device’s control panel: < 5 ms Remote control from PC: < 120 ms |
| Maximum/ Minimum illumination values | Max. Up to 2000 lx for standard D illuminants Min. Down to 25 lx for standard D illuminants | Max. Up to 1000 lux for standard D illuminants Min. Down to 25 lux for standard D illuminants | Max. Up to 2000 lux for standard D illuminants Min. Down to 25 lux for standard D illuminants | - |
Software Downloads
Download the latest version of the iQ-LED Software. Click here for documentation.
Documentation
Download technical specifications and other important documents.